GEIL GAS KILNS
THE GEIL DOWNDRAFT SYSTEM UTILIZES HEAT ENERGY TO ITS FULLEST POTENTIAL THROUGH RECIRCULATION. THIS, OF COURSE MEANS ENERGY SAVINGS AND CONSISTANTLY SUPERIOR RESULTS IN FIRING.
|
|
|
|
|
 |
|
|
|
 |
|
 |
|
|
MODEL
|
INSIDE VOLUME (CF)
|
SETTING SPACE (CF)
|
INSIDE DIM.(WXDXH)
|
OUTSIDE DIM.(WXDXH)
|
STACKING HT
|
SHELF SIZE
|
MAX BTU/HR
|
MAX GAS CONSUMP.CFH
|
GAS LINE INLET
|
# OF BURNERS
|
AVG. FIRING TIME 06/10
|
|
DL-6F
|
10
|
6
|
24X21X33
|
39X48X65
|
33
|
2-9X18/ 1-18X18
|
75000
|
68
|
3/4
|
4
|
4/6HR
|
|
DL-8F
|
12
|
8
|
27X23X33
|
43X50X61
|
33
|
2-10X10/1-20X20
|
100000
|
91
|
3/4
|
4
|
4/6
|
|
DL-12F
|
17
|
12
|
31X27X36
|
47X53X66
|
36
|
2-12X24
|
150000
|
136
|
3/4
|
6
|
4/6
|
|
DL-16F
|
27
|
16
|
39X34X36
|
54X63X65
|
36
|
2-14X24/4-14X14
|
200000
|
181
|
1
|
6
|
4/6
|
|
DL-18F
|
31
|
18
|
39X34X40
|
54X63X70
|
40
|
2-14X28/4-14X14
|
224000
|
203
|
1
|
6
|
4/6
|
|
DL-20F
|
35
|
20
|
48X30X40
|
63X62X70
|
40
|
3-12X24
|
280000
|
254
|
1
|
8
|
4/6
|
|
DL-24F
|
40
|
24
|
43X38X42
|
58X71X72
|
42
|
4-16X16
|
299000
|
271
|
1
|
8
|
4/6
|
|
DL-28F
|
45
|
28
|
43X38X48
|
58X71X78
|
48
|
4-16X16
|
349000
|
317
|
1
|
8
|
4/6
|
|
DL-30F
|
47
|
30
|
43X38X51
|
58X71X81
|
51
|
4-16X16
|
374000
|
340
|
1
|
8
|
6/8
|
|
DL-36F
|
56
|
36
|
48X42X48
|
60X74X78
|
48
|
4-18X18/2-12X18/3-12X24
|
449000
|
408
|
1
|
8
|
6/8
|
|
DL-40F
|
60
|
40
|
48X42X53
|
60X78X80
|
52
|
4-18X18/2-12X18/3-12X24
|
499000
|
453
|
1
|
8
|
6/8
|
|
DL-50F
|
67
|
50
|
48X42X60
|
60X78X88
|
60
|
4-18X18/2-12X18/3-12X24
|
623000
|
566
|
1-1/4
|
10
|
6/8
|
|
DL-60F
|
96
|
60
|
57X47X62
|
72X79X90
|
62
|
8-11X22
|
748000
|
680
|
1-1/4
|
10
|
6/8
|
| * ALL MODELS HAVE A FIRING RANGE FROM 0-2500 F, REQUIRE A MINIMUM OF 6 INCHES WATER COLUMN GAS PRESSURE, AND HAVE THE DD-1 CONTROLLER AS STANDARD EQUIPMENT. |
|
|
|
MODEL
|
INSIDE VOLUME (CF)
|
SETTING SPACE (CF)
|
INSIDE DIM.(WXDXH)
|
OUTSIDE DIM.(WXDXH)
|
STACKING HT
|
SHELF SIZE
|
MAX BTU/HR
|
MAX GAS CONSUMP.CFH
|
GAS LINE INLET
|
# OF BURNERS
|
AVG. FIRING TIME 06/10
|
|
DLB-6
|
10
|
6
|
24X21X33
|
39X48X65
|
33
|
2-9X18/1-18X18
|
99000
|
90
|
3/4
|
4
|
4/6HR
|
|
DLB-8
|
12
|
8
|
27X23X33
|
44X51X65
|
33
|
2-10X20/1-20X20
|
132000
|
120
|
1
|
4
|
4/6
|
|
DLB-12
|
17
|
12
|
31X27X36
|
48X56X67
|
36
|
2-12X24
|
198000
|
180
|
1
|
6
|
4/6
|
|
DLB-16
|
27
|
16
|
39X34X36
|
55X64X66
|
36
|
2-14X28/4-14X14
|
264000
|
240
|
1
|
6
|
4/6
|
|
DLB-18
|
31
|
18
|
39X34X40
|
55X64X73
|
40
|
2-14X28/4-14X14
|
297000
|
270
|
1
|
6
|
4/6
|
|
DLB-20
|
35
|
20
|
48X32X40
|
63X62X73
|
40
|
3-12X24
|
330000
|
300
|
1
|
8
|
4/6
|
|
DLB-24
|
40
|
24
|
43X38X42
|
58X71X73
|
42
|
4-16X16
|
396000
|
360
|
1
|
8
|
4/6
|
|
DLB-28
|
45
|
28
|
43X38X48
|
58X71X79
|
48
|
4-16X16
|
462000
|
420
|
1
|
8
|
4/6
|
|
DLB-30
|
47
|
30
|
43X38X51
|
58X71X82
|
51
|
4-16X16
|
495000
|
450
|
1
|
8
|
6/8
|
|
DLB-36
|
56
|
36
|
48X45X48
|
65X78X79
|
48
|
4-18X18/2-12X18/3-12X24
|
594000
|
540
|
1
|
8
|
6/8
|
|
DLB-40
|
60
|
40
|
48X45X53
|
65X78X83
|
52
|
4-18X18/2-12X18/3-12X24
|
660000
|
600
|
1
|
8
|
6/8
|
|
DLB-50
|
67
|
50
|
48X45X60
|
65X78X91
|
60
|
4-18X18/2-12X18/3-12X24
|
825000
|
750
|
1-1/4
|
10
|
6/8
|
|
DLB-60
|
96
|
60
|
57X47X62
|
72X79X94
|
62
|
8-11X22
|
990000
|
900
|
1-1/4
|
10
|
6/8
|
| * ALL MODELS HAVE A FIRING RANGE FROM 0-2500 F, REQUIRE A MINIMUM OF 6 INCHES WATER COLUMN GAS PRESSURE, AND HAVE THE DD-1 CONTROLLER AS STANDARD EQUIPMENT. |
|
|
|
MODEL
|
INSIDE VOLUME (CF)
|
SETTING SPACE (CF)
|
INSIDE DIM.(WXDXH)
|
OUTSIDE DIM.(WXDXH)
|
STACKING HT
|
SHELF SIZE
|
MAX BTU/HR
|
MAX GAS CONSUMP.CFH
|
GAS LINE INLET
|
# OF BURNERS
|
AVG. FIRING TIME 06/10
|
|
802
|
11
|
8
|
25X22X35
|
35X40X59
|
35
|
2-10X20/1-20X20
|
130000
|
118
|
1/2
|
2
|
2/4HR
|
|
|
|
MODEL
|
INSIDE VOLUME (CF)
|
SETTING SPACE (CF)
|
INSIDE DIM.(WXDXH)
|
OUTSIDE DIM.(WXDXH)
|
STACKING HT
|
SHELF SIZE
|
MAX BTU/HR
|
MAX GAS CONSUMP.CFH
|
GAS LINE INLET
|
# OF BURNERS
|
AVG. FIRING TIME 06/10
|
|
DLB-27S
|
43
|
27
|
51X40X38
|
67X77X72
|
38
|
4-18X18
|
462000
|
420
|
1
|
8
|
4/8HR
|
|
DLB-40S
|
54
|
40
|
51X40X51
|
67X77X85
|
51
|
4-18X18
|
660000
|
600
|
1
|
8
|
4/8
|
|
DLB-54S
|
73
|
54
|
51X54X51
|
67X91X83
|
51
|
6-12X24
|
891000
|
810
|
1
|
10
|
4/8
|
|
DLB-70S
|
99
|
70
|
51X79X44
|
67X105X76
|
44
|
9-12X24
|
1155000
|
1050
|
1-1/4
|
14
|
4/8
|
|
DLB-82S
|
113
|
82
|
51X79X51
|
67X105X83
|
51
|
9-12X24
|
1353000
|
1230
|
1-1/4
|
16
|
4/8
|
|
DLB-100S
|
141
|
100
|
51X102X46
|
67X150X78
|
46
|
12-12X24
|
1650000
|
1500
|
1-1/2
|
20
|
4/8
|
| * ALL MODELS HAVE A FIRING RANGE FROM 0-2500 F, REQUIRE A MINIMUM OF 6 INCHES WATER COLUMN GAS PRESSURE, AND HAVE THE DD-1 CONTROLLER AS STANDARD EQUIPMENT. |
|
|
|
|
Online Catalog *Please note- Prices change without notice, tax and shipping charges are not included. Call, or fax us for an official quote. Phone (714) 541-4157 Fax (714) 541-2021
|
|
|
|
FILL OUT OUR NEW SECURE ONLINE ORDER FORM
CLICK HERE
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|